 DMS-40PC-4/20S
41/2 Digit, 4-20mA Input, LED Display Meters
FEATURES
Full-size, 0.52" (13.2mm) high, LED digits +7.5- 32Vdc model draws 30mA +24V Isolated-power models Dip-switch selectable range, offset, and decimal points Non-interacting, 20-turn, gain (span) and offset (zero) adjustments Insensitive to ground loops 103 Ohm max. loop burden Vibration-resistant package; reliable screw-terminal connections Hundreds of different input/readout combinations Miniature size: 2.17" x 0.92" x 1.02" (55mm x 23mm x 26mm)
The DMS-40PC-4/20S Series' superior design makes them ideal for use in demanding 4-20mA process monitoring applications requiring a full 41/2 digits (0-19999) of display resolution. Their full-size, 0.52" (13.2mm) high, LED displays can be read in virtually any lighting condition and are available in green, high-intensity red, or low-power red. Two operating power supply ranges are available: a wide-input +7.5 to 32V model for use with popular +12Vdc and +24Vdc industrial supplies, and +4.75 to 5.25V models for use with +5V logic supplies. The reverse-polarity protected +7.5-32V red LED model consumes only 30mA from a +24V supply, but still provides excellent display brightness. The DMS-40PC-4/20's input, span, and offset circuits all employ superstable, 0.5% thin-film chip resistors. Long-term stability and accuracy are assured by driving these tight-tolerance resistors with an ultra-stable, 0.2% bandgap voltage reference. And, unlike many competing designs, the two precision 20-turn span and zero adjust potentiometers do not interact with one another. All range-change and decimal point selections are made by configuring two gold-plated, vibration-resistant, six-position DIP switches. To further enhance reliability, both power supply and current loop connections are made via reliable screw-type terminal blocks. All these outstanding features make the DMS-40PC-4/20S Series meters the most rugged 41/2 digit LED display process monitors available.
41/2 DIGIT A/D CONVERTER Range Offset Gain DATA
R3 ZERO ADJUST
R7 GAIN ADJUST
DP1
DP2
DP3
DP4
BAND-GAP REFERENCE CIRCUIT ON S1 1 2 3 4 5 6 S2 1 2 3 4 5 6 ON
+5V
VOLTAGE CONVERTER SG9 +5V CURRENT TO VOLTAGE CONVERTER TB1 1 2 TB2 1 2 1
-V is not connected to meter ground on `-I' suffix models. For full details go to www.murata-ps.com/rohs
+
-
+ +V
- -V
4-20mA CURRENT LOOP POWER
POWER SUPPLY INPUT
Figure 1. DMS-40PC-4/20S Simplified Schematic
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MPM_DMS-40PC-420.D02 Page 1 of 6
DMS-40PC-4/20S
41/2 Digit, 4-20mA Input, LED Display Meters
Performance/Functional Specifications
Typical at TA = +25C, unless otherwise noted. Current Loop Input Full Scale Input Range (1) Loop Burden (2) Voltage Drop (2) Overcurrent Protection Performance Sampling Rate Accuracy (1 minute warm-up) Temperature Drift of Span (3) Temperature Drift of Zero (3) Power Supply Requirements (4) DMS-40PC-4/20S-5RS DMS-40PC-4/20S-5GS DMS-40PC-4/20S-5RH DMS-40PC-4/20S-RL DMS-40PC-4/20S-24RL DMS-40PC-4/20S-24XX-I (models) Display Display Type and Size Polarity Indication Overrange Indication Physical/Environmental Operating Temperature Storage Temperature Humidity (non-condensing) Case Material Weight 0 -40 0 - - - +50 +75 95 C C C 41/2 digit, 0.52"/13.2mm high LED "-" for negative readings "-1_ _ _ " for negative inputs "1_ _ _ " for positive inputs +4.75 to +5.25Vdc at 140mA max. +4.75 to +5.25Vdc at 140mA max. +4.75 to +5.25Vdc at 140mA max. +4.75 to +5.25Vdc at 50mA max. +7.5 to +32Vdc at 50mA max. +21.6 to +26.4Vdc at 60mA max. - - 2.5 reading per second To 0.01%FS 2 Count 0.3 0.2 0.6 0.5 Cnts/C Cnts/C Min. +3.7 12 - - Typ. - - - - Max. +20.4 103 2.1 40 Units mA Ohms Volts mA
TECHNICAL NOTES
(1) Full Scale Input: The DIP Switch settings display readings in Table 1 can typically be obtained with transmitters having a low-level output of 3.7 to 4.3mA and a full-scale output of 19.4 to 20.4mA. When using transmitters whose outputs fall outside these ranges, try using the next highest DIP switch setting if the desired reading is too low, or the next lowest setting if the desired display reading is too high. Example number 2 illustrates this point. Please keep in mind that the DMS-40PC meter from which the DMS40PC-4/20S is derived has an accuracy specification of 3 counts (max.); thus, it may not always be possible to obtain the exact desired display readings. A change of 1 count is defined as the right-hand most digit (the"ones" LED) going up or down by one. Other display readings not shown in Table 1 are obtainable. For example, some negative readings with a 4mA input are possible. Consult DATEL for more information regarding display readings not shown in the table. (2) Loop Impedance/Drop: The maximum loop impedance and the maximum loop voltage-drop are both specified with DIP switch setting #20 enabled. The maximum loop voltage drop is specified with a 20.0mA input current. (3) Temperature Drift: Temperature drift of zero and temperature drift of gain are both specified with the meter configured for range #20 with 4mA adjusted (using R3) to read "0000" 1 count, and 20mA adjusted (using R7) to read "19000" 2 counts. The temperature drift of gain is proportional to the full scale range being used. It is typically less pronounced at the lower range settings, that is, if the observed gain drift of a particular meter is +12 counts when reading "19000" on range #20 at 40C, the same meter will most likely have a drift of only +6 counts when reading "9000" on range #12 at 40C. The normally very accurate autozeroing feature of the DMS-40PC4/20S's internal analog-to-digital converter (A/D) is not a factor in determining the meter's zero-reading stability over temperature due to the fact that an offset voltage is applied to the A/D's LO input. This offset voltage is used to null the voltage developed with a 4ma input. To function properly, the autozeroing feature found in most digital panel meters requires both A/D inputs to remain at zero volts with varying temperature. The meter's zero-reading stability over its specified operating temperature is affected by the drift of three terms: the voltage developed by the meter's offset circuitry; the voltage developed across the meter's input resistor(s) with a 4mA input; and the stability of the applied 4mA input signal itself. In the lower DIP switch settings ( ranges #1-4), the meter's parasitic etch and switch interconnect resistances also contribute a small error. The meter's performance with regards to span stability over temperature is affected by the drift of the meter's gain circuitry and the drift of the input resistor(s). To counter these drifts in applications requiring the utmost in temperature stability, where possible, the meter should be calibrated at its anticipated operating temperature. For these applications, use of the DMS-40PC-4/20S-5RL model is highly recommended because of its inherently lower power consumption and self-heating.
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
Polycarbonate 0.1 ounces (28 grams)
Ordering Information
DMS-40PC-4/20S-5RS DMS-40PC-4/20S-5GS DMS-40PC-4/20S-5RL DMS-40PC-4/20S-5RH DMS-40PC-4/20S-24RL DMS-40PC-4/20S-24RS-I DMS-40PC-4/20S-24RH-I DMS-40PC-4/20S-24GS-I DMS-BZL1 DMS-BZL2 DMS-30-CP +5V supply, standard-intensity red LED's +5V supply, standard-intensity green LED's +5V supply, low-power red LED's +5V supply, high-intensity red LED's +7.5V to +32V supply, low-power red LED's +24V isolated supply, standard-intensity red LED's +24V isolated supply, high-intensity red LED's +24V isolated supply, standard-intensity green LED's Panel-mount bezel assembly Panel-mount bezel assembly with sealing gasket Panel cutout punch
A panel-mount retaining clip is supplied with each meter.
www.murata-ps.com
MPM_DMS-40PC-420.D02 Page 2 of 6
DMS-40PC-4/20S
41/2 Digit, 4-20mA Input, LED Display Meters
Table 1. DIP-Switch Settings
Switch S1 Display Reading 4mA 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 20mA 2250-2500 2500-2800 2800-3200 3200-3850 3850-4300 4300-4900 4900-5600 5600-6200 6200-6800 6800-7750 7750-8600 8600-9850 9850-11000 11000-12000 12000-13000 13000-14000 14000-15300 15300-16300 16300-17800 17800-20000 Off Off Off Off On On On On Off Off On On On On On On On On Off Off On On On On Off Off Off Off Off Off On On On On Off Off Off Off Off Off On On On On On On On On On On Off Off On On Off Off On On On On On On On On On On On On On On On On Off Off On On Off Off Off Off Off Off Off Off Off Off Off Off On On On On Off Off Off Off On On On On Off Off Off Off Off Off Off Off Off Off Off Off On On On On On On On On On Off On Off On Off On Off On Off On Off On Off On Off On Off On Off On On Off Off On On Off Off On On On On On On On On On On On On SW1 SW2 SW3 SW4 SW5 SW6 Switch S2 SW1 SW2
Since the DMS-40PC-4/20S uses extremely-stable thin-film chip resistors, periodic re-calibration is typically required only in environmentally demanding applications where shock, vibration and temperature extremes may have a detrimental affect on the 20-turn potentiometers. (4) Input Grounding: Except for the "-I" suffix models which feature isolated current loop inputs, all other DMS-40PC-4/20S meters are supplied with their 4-20mA negative-input terminals (TB1-2, "-") internally connected to their power supply ground terminal (TB2-2, "-V"). This single-ended input configuration is compatible with most grounded-referenced 4-20mA transmitters. Applications in which the DMS-40PC-4/20S and its associated 4-20mA transmitter are connected to a common ground and the transmitter drives two or more loads (for example, the meter is in series with a PLC) must have the meter connected as the first device in the current loop, that is, closest to the system ground (see Figure 2). If this connection scheme is not possible and/or the meter must be connected in the middle of the current loop, then`-I' suffix models must be used to provide the required isolation between the meter's current loop input and the power supply ground ("-V"). See Figures 2, 3, 4, and 5 for typical loop connections.
Using the Decimal Point Settings Table as a guide, the DMS-40PC4/20S's decimal points can be enabled to suit the user's particular readout requirements. Place the selected decimal point's DIP switch to the ON position (up) to illuminate the decimal point. The decimal points are merely placeholders, that is, they can all be illuminated or all turned off; they have no affect on the meter's operation and/or display readings.
OPERATING AND SETUP INSTRUCTIONS
The following procedure must be performed as the first re-calibration step every time DIP switches S1 and S2 are changed to select a new display range. The following procedure also assumes the DMS-40PC-4/20S is initially completely mis-adjusted, i.e., both potentiometers and both DIP switches S1 and S2 are randomly set. When performing switch settings, make sure that the DIP switch's small actuator is pushed up as far as it will go to ensure that the switch is truly set to the ON (closed) position. 1. Set R7 (gain/span adjust) and R3 (zero/offset adjust) fully clockwise, roughly 20 turns, then using the settings found in the selected range, place the DIP switches on S1 and S2 to the appropriate positions for the desired display reading. 2. Apply a precision 4mA input with proper polarity and adjust R3 (top 20-turn potentiometer) until the meter's display reads "0000". 3. Apply a precision 20mA input and adjust R7 (bottom 20-turn potentiometer) until the display reads the maximum desired reading. Repeat steps 2 and 3 to make sure the adjustments did not affect one another.
Table 2. Decimal Point Settings
Switch S2 SW3 DP1 SW4 DP2 SW5 DP3 SW6 DP4
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MPM_DMS-40PC-420.D02 Page 3 of 6
DMS-40PC-4/20S
41/2 Digit, 4-20mA Input, LED Display Meters
4. If necessary, select the appropriate decimal point by setting either SW3, SW4, SW5, or SW6 of S2 to ON (DP1, DP2, DP3, or DP4, respectively, as shown in Table 2). NOTE: Please keep in mind that the transmitter's 4mA and 20mA output accuracy may affect display readings which are at, or very close to, the high and low extremes of the selected range. See Example #2 below and Technical Note 1 for more information. Use DIP-switch setting #11. Apply 4mA and adjust R3 so the display reads "0000". Apply 20mA and adjust R7 so the display reads "8600". If the transmitter's full-scale output is less than 20.0mA, it may not be possible to adjust R7 for a reading of "8600" with setting #11. If this occurs, select setting #12 and re-calibrate both R3 and R7 to obtain "0000" and "8600". Note that for these display readings no decimal points are used. Set SW3, SW4, SW5 and SW6 on switch S2 to OFF. S1 S2 3. Desired display readings are:
ON ON
Examples
The examples below illustrate how to configure the meter to perform some typical measurements. Remember to first set R3 and R7 to their full clockwise position before calibrating the meter. S1 S2 1. Desired display readings are:
ON
4mA = "0000" 20mA = "10000"
1
2
3
4
5
6
1
2
4mA = "0.000" 20mA = "3.000"
1 2 3 4 5 6 1 2
Use DIP-switch setting #13. Apply 4mA and adjust R3 so the display reads "0000". Apply 20mA and adjust R7 so the display reads "10000". For these display readings no decimal points are used. Set SW3, SW4, SW5 and SW6 on switch S2 to OFF. S1 S2 4. Desired display readings are:
ON ON
Use DIP-switch setting #3 and enable decimal point DP2 by placing SW4 of switch S2 to ON. Apply 4mA and adjust R3 so the display reads "0.000". Apply 20mA and adjust R7 so the display reads "3.000". 2. Desired display readings are: 4mA = "0000" 20mA = "8600"
1 2 3
4mA = ".0000" 12mA = ".2500"
1
2
3
4
5
6
1
2
S1
ON ON
S2
4
5
6
1
2
This example is not as straightforward as the previous three. Notice that 12mA is exactly halfway between 4mA and 20mA. If we assume the input could go up to 20mA, the display reading would then be 2 x .2500 or ".5000". From the table, we can select DIP-switch setting #7 and enable DP1 via SW3 of switch S2. Apply 4mA and adjust R3 so the display reads ".0000". Apply 12mA and adjust R7 so the display reads ".2500".
CONNECTION DIAGRAMS
+24V
+ +
4-20mA SINGLE-ENDED TRANSMITTER (TB1-1)
+V (TB2-1)
+
DMS-40PC-4/20S-24RL
-
24V GROUND
(TB1-2)
-
-V (TB2-2)
Figure 2. Typical Connections for Single-Ended Transmitters Driving Single-Ended +24V Powered Meters.
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MPM_DMS-40PC-420.D02 Page 4 of 6
DMS-40PC-4/20S
41/2 Digit, 4-20mA Input, LED Display Meters
+24V
+
(TB1-1) LOOP-POWERED TRANSMITTER
+V (TB2-1)
+
DMS-40PC-4/20S-24RL
-
4-20mA N.C. (TB1-2)
-
-V (TB2-2) 24V GROUND
Figure 3. Typical Connections for Loop-Powered Transmitters Driving Single-Ended Meters.
Figure 4. Typical Connections for Isolated-Supply Meters in Series with an Auxiliary Device.
+24V
+5V
+ +
4-20mA LOOP TRANSMITTER (TB1-1)
+V (TB2-1)
+
DMS-40PC-4/20S-24RL
-
24V GROUND
(TB1-2)
-
-V (TB2-2) 5V GROUND
Figure 5. Typical Connections for +5V Powered Meters. Note that 5V Ground and 24V Ground are Tied Together Inside the Meter.
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MPM_DMS-40PC-420.D02 Page 5 of 6
DMS-40PC-4/20S
41/2 Digit, 4-20mA Input, LED Display Meters
MECHANICAL DIMENSIONS: Inches (mm) TOLERANCES: WIRE SIZE: STRIPPING LENGTH: 2 PL DEC 0.02 (0.51) 3 PL DEC 0.010 (0.254) 18 to 26 AWG (Solid or stranded) 0.20" (5.08mm)
U2 U2
1.33 (33.8)
1 1.02 (25.9)
0.040 (1.02)
2.09 (53.09) 2.17 (55.12) 1 Depth dimension for the DMS-40PC-4/20S-24RL model only. U2 is not used on 5V-powered models.
Back View
S1
ON ON
Front View
S2
PS1
1
2
3
4
5
6
1
2
3
4
5
6
R3 Zero R7 Span
TB1 + - + -
TB2 U2
7
R7
1
2
1
2
Loop Input
+-+-
SG9
Power Input
DP1 S2 (SW3)
DP2 S2 (SW4)
DP3 S2 (SW5)
FRONT VIEW
#2-56 INSERT 0.156 (3.96) DEEP
0.187 (4.75)
1.270 (32.26)
(R) (R)
2.55 (64.77)
RECOMMENDED DRILL AND PANEL CUTOUT DIMENSIONS
INTERNAL CORNER RADII: 0.032 (0.81) MAX. 0.116 (2.95)
RETAINING CLIP INSTALLATION
1.07 (27.18)
PANEL CUTOUT
0.878 (22.30)
2.118 (53.80)
(R) (R)
0.093 (2.362) DIAMETER (4 REQUIRED) ONLY WHEN USING OPTIONAL BEZEL ASSEMBLY
0.096 (2.44)
A panel-mount retaining clip is supplied with all models.
USA: Canada: UK: France: Germany: Japan: China: Singapore:
Mansfield (MA), Tel: (508) 339-3000, email: sales@murata-ps.com Toronto, Tel: (866) 740-1232, email: toronto@murata-ps.com Milton Keynes, Tel: +44 (0)1908 615232, email: mk@murata-ps.com Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: france@murata-ps.com Munchen, Tel: +49 (0)89-544334-0, email: munich@murata-ps.com Tokyo, Tel: 3-3779-1031, email: sales_tokyo@murata-ps.com Osaka, Tel: 6-6354-2025, email: sales_osaka@murata-ps.com Shanghai, Tel: +86 215 027 3678, email: shanghai@murata-ps.com Guangzhou, Tel: +86 208 221 8066, email: guangzhou@murata-ps.com Parkway Centre, Tel: +65 6348 9096, email: singapore@murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A. Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356
www.murata-ps.com email: sales@murata-ps.com ISO 9001 and 14001 REGISTERED
11/25/08
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. (c) 2008 Murata Power Solutions, Inc.
www.murata-ps.com
MADE IN USA
2.35 (59.69)
DMS-40PC-4/20S
DP4 S2 (SW6)
BEZEL INSTALLATION
(R)
MADE IN USA
(R)
MADE IN USA
0.04 (1.02)
0.84 (21.34) 0.92 (23.37)
PANEL
OPTIONAL GASKET BEZEL
PANEL
MPM_DMS-40PC-420.D02 Page 6 of 6


▲Up To Search▲   

 
Price & Availability of DMS-40PC-420S-24GS-I

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X